Temperature Data Logger

In order to cater to the variegated requirements of our clients, we have been able to offer supreme quality Temperature Data Logger. This range includes Temp/Humid/Pressure Transmitter With Ethernet, Temp/Humid/Pressure Monitor, Temp/Humid/Pressure Regulator With RS-232, Temp/Humid/Pressure Regulator With RS-485 and Temp/Humid/Pressure Sensor With Ethernet, to name a few. These loggers are manufactured utilizing latest technology as per the set industry standards and norms.

Temp/Humid/Pressure Transmitter with Ethernet

GET CALLBACK
Temp/Humid/Pressure Transmitter with EthernetClick to Zoom

Get Best Quote

We are readily engaged in delivering Temp/Humid/Pressure Transmitter with Ethernet to respectable clients. The offered range of transmitters is made utilizing high grade raw material and innovative technology in complete adherence with the industry laid norms and standards. Along with this, the offered range is acclaimed in the market for its thermal resistance and trouble-free operations.

 

Specifications:

 

  • Output: Ethernet
  • Measured value: Relative humidity + temperature + atmospheric pressure
  • Construction type: With T+RH probe on cable
  • Design: Industrial
  • Temperature measuring range: -30 to +105 °C
  • Relay output: Yes
  • Two-state input: Yes
  • LCD display: Yes
  • Relative humidity range: 0 to 100%
  • Accuracy of relative humidity measurement: ±2.5% relative humidity from 5 to 95% at 23 °C
  • Accuracy of temperature output: ±0.4 °C
  • Maximum measuring pressure range: 600 to 1100 h Pa
  • Accuracy: ±1.3 hPa at 23 °C
  • Resolution :0.1 °C, 0.1% RH and 0.1 h Pa
  • Measuring interval: 2 s
  • Available temperature units: Degrees celcius and degrees Fahrenheit
  • Computed value: Dew point, absolute humidity, specific humidity, mixing ratio and specific enthalpy
  • Available pressure units: h Pa, k Pa, m bar, mm Hg, in Hg, in H2O, PSI and oz/in2
  • Accuracy and range of dew point temperature output: ±1.5 °C at ambient temperature T<25 °C and RH>30% range -60 to +80 °C
  • Accuracy and range of absolute humidity output: ±1.5 g/m3 at ambient temperature T < 25 °C range 0 to 400 g/m3
  • Accuracy and range of specific humidity output: ±2 g/kg at ambient temperature T < 35 °C range 0 to 550 g/kg
  • Accuracy and range of mixing ratio output: ±2 g/kg at ambient temperature T < 35 °C range 0 to 995 g/kg
  • Accuracy and range of specific enthalpy output: ±3 kJ/kg at ambient temperature T < 25 °C range: 0 to 995 kJ/kg
  • Temperature compensation of the humidity sensor:all temperature range
  • Temperature operating range: -30 to +80 °C
  • IP protection: IP 40
  • Number of relay outputs: 2
  • Max switching voltage/current/power of relay output: 50 V, 2 A and 60 VA
  • Number of binary inputs: 3
  • Signal for binary inputs:Dry contact, open collector or two-state voltage signal. Inputs are not galvanically isolated
  • Minimum pulse length at binary input: 500 ms
  • Low voltage level: 0 to +0.5 V
  • High voltage level: +3.0 to +30 V
  • Audible alarm: Built-in beeper - switchable
  • LAN connection: RJ-45 connector and 10 base-T/100 base-TX
  • Communication protocols: WWW, Modbus TCP, SNMPv1 and SOAP
  • Alarm protocols: E-mail (SMTP authentication is supported), SNMP Trap, sys-log
  • Configuration: T-sensor, telnet, keyboard
  • Temperature operating range of LCD display: Readable to operating temperature +70 °C, it is recommended to switch OFF the LCD over +70 °C
  • Filtering ability of sensor cover: 0.025 mm - filter with stainless steel mesh
  • Power: 9 to 30 V DC, maximum consumption 1 W
  • Power connector: Co-axial and diameter 5.5 x 2.1 mm
  • Length of the probe cable: 1 m and 2 m/4 m optionally
  • Dimensions: 136 x 159 x 45 mm (W x H x D), probe length 88 mm, probe diameter 18 mm
  • Weight: Approximately 410 g - 1 m probe

Yes! I am Interested

Temp/Humid/Pressure Sensor with Ethernet

GET CALLBACK
Temp/Humid/Pressure Sensor with EthernetClick to Zoom

Get Best Quote

Our customers can avail Temp/Humid/Pressure Sensor with Ethernet from us. The offered range of sensors is made utilizing high grade raw material and innovative techniques in strict compliance with the international quality norms and standards. Along with this, the offered range of sensors is appreciated for its performance and durability.

 

Specifications:

 

  • Output: Ethernet
  • Measured value: Relative humidity + temperature + atmospheric pressure
  • Construction type: Ambient air
  • Design: Industrial
  • Temperature measuring range: -30 to +80 °C
  • Relay output: Yes
  • Two-state input: Yes
  • LCD display: Yes
  • Relative humidity range: 0 to 100%
  • Accuracy of relative humidity measurement: ±2.5% relative humidity from 5 to 95% at 23 °C
  • Accuracy of temperature output: ±0.4 °C
  • Maximum measuring pressure range: 600 to 1100 h Pa
  • Accuracy: ±1.3hPa at 23 °C
  • Resolution :0.1 °C, 0.1% RH and 0.1 h Pa
  • Measuring interval: 2 s
  • Available temperature units: Degrees celcius and degrees Fahrenheit
  • Computed value: Dew point, absolute humidity, specific humidity, mixing ratio and specific enthalpy
  • Available pressure units: h Pa, k Pa, m bar, mm Hg, in Hg, in H2O, PSI and oz/in2
  • Accuracy and range of dew point temperature output: ±1.5 °C at ambient temperature T<25 °C and RH>30% range -60 to +80 °C
  • Accuracy and range of absolute humidity output: ±1.5 g/m3 at ambient temperature T < 25 °C range 0 to 400 g/m3
  • Accuracy and range of specific humidity output: ±2 g/kg at ambient temperature T < 35 °C range 0 to 550 g/kg
  • Accuracy and range of mixing ratio output: ±2 g/kg at ambient temperature T < 35 °C range 0 to 995 g/kg
  • Accuracy and range of specific enthalpy output: ±3 kJ/kg at ambient temperature T < 25 °C range: 0 to 995 k J/kg
  • Temperature compensation of the humidity sensor:all temperature range
  • Temperature operating range: -30 to +80 °C
  • IP protection: IP 40 & IP 54
  • Number of relay outputs: 2
  • Max switching voltage/current/power of relay output: 50 V, 2 A and 60 VA
  • Number of binary inputs: 3
  • Signal for binary inputs: Dry contact, open collector or two-state voltage signal. Inputs are not galvanically isolated
  • Minimum pulse length at binary input: 500 ms
  • Low voltage level: 0 to +0.5 V
  • High voltage level: +3.0 to +30 V
  • Audible alarm: Built-in beeper - switchable
  • LAN connection: RJ-45 connector and 10 base-T/100 base-TX
  • Communication protocols: WWW, Modbus TCP, SNMPv1 and SOAP
  • Alarm protocols: E-mail (SMTP authentication is supported), SNMP Trap, sys-log
  • Configuration: T-sensor, telnet, keyboard
  • Temperature operating range of LCD display: Readable to operating temperature +70 °C, it is recommended to switch OFF the LCD over +70 °C
  • Filtering ability of sensor cover: 0.025 mm - filter with stainless steel mesh
  • Power: 9 to 30 V DC, maximum consumption 1 W
  • Power connector: Co-axial and diameter 5.5 x 2.1 mm
  • Length of the probe cable: 1 m and 2 m/4 m optionally
  • Dimensions: 136 x 213 x 45 mm (W x H x D), probe length 75 mm, probe diameter 18 mm
  • Weight: Approximately 360 g

Yes! I am Interested

Temp/Humid/Pressure Regulator with RS-232

GET CALLBACK
Temp/Humid/Pressure Regulator with RS-232Click to Zoom

Get Best Quote

We are an eminent name, which is engaged in delivering Temp/Humid/Pressure Regulator with RS - 232. The offered range of regulators is available in different customized specifications to comprehend and meet the diverse requirements of esteemed clients. Along with this, the offered range of regulators is acclaimed in the market for its Relay and RS 232 outputs.

 

Specifications:

 

  • Output: RS 232
  • Measured value: Relative humidity + temperature + atmospheric pressure
  • Construction type: With T+RH probe on cable
  • Design: Industrial
  • Temperature measuring range: -30 to +105 °C
  • Relay output: Yes
  • Two-state input: Yes
  • LCD display: Yes
  • Relative humidity range: 0 to 100%
  • Accuracy of relative humidity measurement: ±2.5% relative humidity from 5 to 95% at 23 °C
  • Accuracy of temperature output: ±0.4 °C
  • Maximum measuring pressure range: 600 to 1100 h Pa
  • Accuracy: ±1.3 hPa at 23 °C
  • Resolution :0.1 °C, 0.1% RH and 0.1 h Pa
  • Measuring interval: 2 s
  • Available temperature units: Degrees celcius and degrees Fahrenheit
  • Computed value: Dew point, absolute humidity, specific humidity, mixing ratio and specific enthalpy
  • Available pressure units: h Pa, k Pa, m bar, mm Hg, in Hg, in H2O, PSI and oz/in2
  • Accuracy and range of dew point temperature output: ±1.5 °C at ambient temperature T<25 °C and RH>30% range -60 to +80 °C
  • Accuracy and range of absolute humidity output: ±1.5 g/m3 at ambient temperature T < 25 °C range 0 to 400 g/m3
  • Accuracy and range of specific humidity output: ±2 g/kg at ambient temperature T < 35 °C range 0 to 550 g/kg
  • Accuracy and range of mixing ratio output: ±2 g/kg at ambient temperature T < 35 °C range 0 to 995 g/kg
  • Accuracy and range of specific enthalpy output: ±3 k J/kg at ambient temperature T < 25 °C range: 0 to 995 k J/kg
  • Temperature compensation of the humidity sensor:all temperature range
  • Temperature operating range: -30 to +80 °C
  • IP protection: IP 40
  • Number of relay outputs: 2
  • Max switching voltage/current/power of relay output: 50 V, 2 A and 60 VA
  • Number of binary inputs: 3
  • Signal for binary inputs:Dry contact, open collector or two-state voltage signal. Inputs are not galvanically isolated
  • Minimum pulse length at binary input: 500 ms
  • Low voltage level: 0 to +0.5 V
  • High voltage level: +3.0 to +30 V
  • Audible alarm: Built-in beeper - switchable
  • LAN connection: RJ - 45 connector and 10 base-T/100 base-TX
  • Communication protocols: WWW, Modbus TCP, SNMPv1 and SOAP
  • Alarm protocols: E-mail (SMTP authentication is supported), SNMP Trap, sys-log
  • Configuration: T-sensor, telnet, keyboard
  • Temperature operating range of LCD display: Readable to operating temperature +70 °C, it is recommended to switch OFF the LCD over +70 °C
  • Filtering ability of sensor cover: 0.025 mm - filter with stainless steel mesh
  • Power: 9 to 30 V DC, maximum consumption 1 W
  • Power connector: Co-axial and diameter 5.5 x 2.1 mm
  • Length of the probe cable: 1 m and 2 m/4 m optionally
  • Dimensions: 136 x 159 x 45 mm (W x H x D), probe length 88 mm, probe diameter 18 mm
  • Weight: Approximately 500 g

Yes! I am Interested

Temp / Humid / Pressure Monitor

GET CALLBACK
Temp / Humid / Pressure MonitorClick to Zoom

Get Best Quote

With an immense experience and a competent team of professionals, we are able to deliver Temp/Humid/Pressure Monitor. The offered range of monitors is designed utilizing high grade components, sourced from trustworthy vendors of the market. Our proficient quality personnel ensure to check the entire range of monitors on different parameters to ensure its adherence with the international quality norms and standards.

 

Specifications:

 

  • Output: Ethernet
  • Measured value: Relative humidity + temperature + atmospheric pressure
  • Construction type: With T+RH probe on cable
  • Design: Industrial
  • Temperature measuring range: -30 to +105 °C
  • Relay output: Yes
  • Two-state input: Yes
  • LCD display: Yes
  • Relative humidity range: 0 to 100%
  • Accuracy of relative humidity measurement: ±2.5% relative humidity from 5 to 95% at 23 °C
  • Accuracy of temperature output: ±0.4 °C
  • Maximum measuring pressure range: 600 to 1100 h Pa
  • Accuracy: ±1.3 hPa at 23 °C
  • Resolution :0.1 °C, 0.1% RH and 0.1 h Pa
  • Measuring interval: 2 s
  • Available temperature units: Degrees celcius and degrees Fahrenheit
  • Computed value: Dew point, absolute humidity, specific humidity, mixing ratio and specific enthalpy
  • Available pressure units: h Pa, k Pa, m bar, mm Hg, in Hg, in H2O, PSI and oz/in2
  • Accuracy and range of dew point temperature output: ±1.5 °C at ambient temperature T<25 °C and RH>30% range -60 to +80 °C
  • Accuracy and range of absolute humidity output: ±1.5 g/m3 at ambient temperature T < 25 °C range 0 to 400 g/m3
  • Accuracy and range of specific humidity output: ±2 g/kg at ambient temperature T < 35 °C range 0 to 550 g/kg
  • Accuracy and range of mixing ratio output: ±2 g/kg at ambient temperature T < 35 °C range 0 to 995 g/kg
  • Accuracy and range of specific enthalpy output: ±3 kJ/kg at ambient temperature T < 25 °C range: 0 to 995 kJ/kg
  • Temperature compensation of the humidity sensor:all temperature range
  • Temperature operating range: -30 to +80 °C
  • IP protection: IP 40
  • Number of relay outputs: 2
  • Max switching voltage/current/power of relay output: 50 V, 2 A and 60 VA
  • Number of binary inputs: 3
  • Signal for binary inputs:Dry contact, open collector or two-state voltage signal. Inputs are not galvanically isolated
  • Minimum pulse length at binary input: 500 ms
  • Low voltage level: 0 to +0.5 V
  • High voltage level: +3.0 to +30 V
  • Audible alarm: Built-in beeper - switchable
  • LAN connection: RJ-45 connector and 10 base-T/100 base-TX
  • Communication protocols: WWW, Modbus TCP, SNMPv1 and SOAP
  • Alarm protocols: E-mail (SMTP authentication is supported), SNMP Trap, sys-log
  • Configuration: T-sensor, telnet, keyboard
  • Temperature operating range of LCD display: Readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70 °C
  • Filtering ability of sensor cover: 0.025 mm - filter with stainless steel mesh
  • Power: 9 to 30 V DC, maximum consumption 1 W
  • Power connector: Co-axial and diameter 5.5 x 2.1 mm
  • Length of the probe cable: 1 m and 2 m/4 m optionally
  • Dimensions: 136 x 159 x 45 mm (W x H x D), probe length 88 mm, probe diameter 18 mm
  • Weight: Approximately 410 g - 1 m probe

Yes! I am Interested

Temp/Humid/Pressure Regulator

GET CALLBACK
Temp/Humid/Pressure RegulatorClick to Zoom

Get Best Quote

In order to append and respond to the diverse requirements of esteemed clients, we are able to offer Temp/Humid/Pressure Regulator With RS-485. The offered range of regulators is manufactured utilizing premium grade raw material and innovative technology that are handled by diligent personnel. Along with this, our quality experts make sure to inspect the entire assembly of regulators utilizing stringent methods to maintain its standards.

 

Specifications:

 

  • Output: RS232
  • Measured value: Relative humidity + temperature + atmospheric pressure
  • Construction type: Ambient air
  • Design: Industrial
  • Temperature measuring range: -30 to +80°C
  • Relay output: Yes
  • Two-state input: Yes
  • LCD display: Yes
  • Relative humidity range: 0 to 100%
  • Accuracy of relative humidity measurement: ±2.5% relative humidity from 5 to 95% at 23°C
  • Accuracy of temperature output: ±0.4°C
  • Maximum measuring pressure range: 600 to 1100 h Pa
  • Accuracy: ±1.3hPa at 23°C
  • Resolution :0.1°C, 0.1% RH and 0.1 h Pa
  • Measuring interval: 2 s
  • Available temperature units: Degrees celcius and degrees Fahrenheit
  • Computed value: Dew point, absolute humidity, specific humidity, mixing ratio and specific enthalpy
  • Available pressure units: h Pa, k Pa, m bar, mm Hg, in Hg, in H2O, PSI and oz/in2
  • Accuracy and range of dew point temperature output: ±1.5°C at ambient temperature T<25°C and RH>30% range -60 to +80°C
  • Accuracy and range of absolute humidity output: ±1.5 g/m3 at ambient temperature T < 25°C range 0 to 400 g/m3
  • Accuracy and range of specific humidity output: ±2 g/kg at ambient temperature T < 35°C range 0 to 550 g/kg
  • Accuracy and range of mixing ratio output: ±2 g/kg at ambient temperature T < 35°C range 0 to 995 g/kg
  • Accuracy and range of specific enthalpy output: ±3 kJ/kg at ambient temperature T < 25°C range: 0 to 995 kJ/kg
  • Temperature compensation of the humidity sensor:all temperature range
  • Temperature operating range: -30 to +80°C
  • IP protection: IP 40 & IP 54
  • Number of relay outputs: 2
  • Max switching voltage/current/power of relay output: 50 V, 2 A and 60 VA
  • Number of binary inputs: 3
  • Signal for binary inputs: Dry contact, open collector or two-state voltage signal. Inputs are not galvanically isolated
  • Minimum pulse length at binary input: 500 ms
  • Low voltage level: 0 to +0.5 V
  • High voltage level: +3.0 to +30 V
  • Audible alarm: Built-in beeper - switchable
  • LAN connection: RJ-45 connector and 10 base-T/100 base-TX
  • Communication protocols: ModBus RTU and Advantech ADAM compatible protocol
  • Alarm protocols: E-mail (SMTP authentication is supported), SNMP Trap, sys-log
  • Configuration: T-sensor, telnet, keyboard
  • Temperature operating range of LCD display: Readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C
  • Filtering ability of sensor cover: 0.025 mm - filter with stainless steel mesh
  • Power: 9 to 30 V DC, maximum consumption 1 W
  • Power connector: Co-axial and diameter 5.5 x 2.1 mm
  • Length of the probe cable: 1 m and 2 m/4 m optionally
  • Dimensions: 136 x 213 x 45 mm (W x H x D), probe length 75 mm, probe diameter 18 mm
  • Weight: Approximately 360 g